In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
Development of the pulsation device for rotary blood pumps
Tomoyuki Yambe1, Yasuyuki Shiraishi, Kazumitsu Sekine
1Department of Medical Engineering and Cardiology, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan. yambe@idac.tohoku.ac.jp
Abstract:
A rotary blood pump (RP) is desirable as a small ventricular assist device (VAD). However, an RP is nonpulsatile. We tried to develop a device that attaches a pulse to the RP. We also tried to develop a pulse-generating equipment that was not air-pressure driven. The ball screw motor was considered a candidate. The application of a small-sized shape memory alloy was also attempted. An electrohydraulic system was adopted, and actuator power was connected to the diaphragm. The diaphragm was placed on the outer side of the ventricle. Most RPs that have been developed all over the world drain blood from the ventricle. The wave of a pulse should be generated if a pulse is added by the drawn part. The output assistance from the outer side of the ventricle was attempted in animal experiments, and the device operated effectively. This device can be used during implantable operation of RP. This may serve as an effective device in patients experiencing problems in peripheral circulation and in the function of internal organs.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: