Related Experiment Video
Updated: Aug 15, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
An association between oxygen desaturation and D-dimer in patients with obstructive sleep apnea syndrome
David Shitrit1, Nir Peled, Ariella Bar-Gil Shitrit
1Pulmonary Institute, Rabin Medical Center, Beilinson Campus, Petah Tiqwa, and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Abstract:
D-dimer, a degradation product of fibrin, is being increasingly used as a marker and prognostic factor in various thrombotic diseases. Previous reports have shown that obstructive sleep apnea is associated with platelet activation and hypercoagulability. The aim of the study was to assess the potential role of the plasma D-dimer test in patients with obstructive sleep apnea. We designed a prospective group comparison study in a tertiary-care, university-affiliated medical center. One hundred and three patients of mean age 57 years (range 50-76 years) with symptoms suggestive of obstructive sleep apnea were included. Polysomnography was performed in all cases, and blood was collected for plasma D-dimer measurement by MiniQuant turbidmetric assay. The demographic and polysomnograph data were compared between patients with normal and high (> 250 ng/ml) D-dimer levels. The group with higher D-dimer values had lower mean minimal oxygen saturation (72.1 +/- 16.4 vs. 81.7 +/- 11.6%, p = 0.008) and a longer mean period of oxygen saturation below 90% (84.1 +/- 86.2 vs. 38.5 +/- 70.8 minutes, p = 0.032). There was no correlation of respiratory disturbance index and sleep architecture with D-dimer values. We concluded that sleep apnea syndrome is associated with fibrinolytic activity. Oxygen desaturation seems to be one of the mediatory factors in the putative connection between obstructive sleep apnea and hypercoagulability state.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Acute Respiratory Failure-IV
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...