SPE-GC-MS for the sampling and determination of unmetabolized styrene in urine
1Instituto de Seguridad y Salud Laboral, El Palmar, Región de Murcia, Spain. celiaa.prado@carm.es
Abstract:
The urinary excretion of unmetabolized styrene can be a very good indicator for biomonitoring styrene in occupationally exposed people. The use of a new urine sampling system, involving a solid-phase extraction cartridge, offers several advantages for determining styrene. The advantages are especially related to the pre-analytical phase of styrene determination, which may be influenced by many variables. The effect on styrene recovery of sorbent type, eluting solvent, elution volume, elution flow-rate, and the addition of methanol to the washing solvent, was evaluated by experimental design methodology. As a result, Oasis HLB cartridges were selected for urine sampling, as well as 1.5 mL of ethyl acetate at 0.5 mL/min for eluting the retained styrene. These conditions were then applied to the validation of the solid-phase extraction combined with GC-MS method for the sampling and analysis of unmetabolized styrene in urine. The overall uncertainty was in the 12-22% range and the limit of detection was 2.2 microg/L for a 4 mL urine sample. The stability of styrene has been studied both in cartridges and in vials under different storage periods. After 1 month period the styrene stored on cartridges at room temperature remained stable, whereas this is not the case for styrene recovery from vials. The results obtained indicate that on-site solid-phase extraction of urine can provide a simple, accurate and reproducible sampling and analytical method for the biomonitoring of styrene in urine.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.