Usefulness of a saline flush for intravenous 3-dimensional computed tomography portography using multidetector-row
Munetaka Matoba1, Tamaki Kondou, Hajime Yokota
1Department of Radiology, Kanazawa Medical University, Ishikawa, Japan. m-matoba@kanazawa-med.ac.jp
Purpose:
To evaluate the clinical usefulness of a saline flush technique in improving the imaging quality of 3-dimensional computed tomography portography (3D-CTP).
Methods:
To evaluate liver metastases, 58 patients were divided into 2 groups undergoing 3D-CTP with or without a saline flush. The computed tomography (CT) values of the right portal vein (RPV), left portal vein (LPV), main portal vein (MPV), and right hepatic parenchyma (RHP) were assessed. Maximum intensity projection (MIP) 3D-CTP images were evaluated by vessel visualization.
Results:
Higher mean CT attenuation values in the RPV, LPV, MPV, and RPV-RHP were observed in the saline flush group and were statistically significant (P = 0.04, P = 0.03, P = 0.01, and P = 0.04, respectively). The difference in imaging quality between 2 groups was statistically significant (P = 0.04). In segment VIII, the ability to depict the segmental branches was significantly higher when the saline flush technique was used (P = 0.03).
Conclusions:
The saline flush technique increases the CT attenuation values of the portal vein and the difference in values between the portal vein and the tissue around it and improves the MIP imaging quality of 3D-CTP.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...