Human factors as a source of error in peak Doppler velocity measurement

Elaine Y L Lui1, Aaron H Steinman, Richard S C Cobbold

  • 1Institute of Biomaterials and Biomedical Engineering, University of Toronto, Ontario, Canada. elaine.lui@utoronto.ca

Abstract

Related Concept Videos

Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
Doppler Effect - I00:56

Doppler Effect - I

The Doppler effect and Doppler shift were named after the Austrian physicist and mathematician Christian Johann Doppler in 1842, who conducted experiments with both moving sources and moving observers. Consider an observer standing on a street corner, observing an ambulance with a siren sound passing by at a constant speed. The observer experiences two characteristic changes in the sound of the siren. Initially, the sound increases in loudness as the ambulance approaches and decreases in...
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Doppler Effect - II01:05

Doppler Effect - II

The Doppler effect has several practical, real-world applications. For instance, meteorologists use Doppler radars to interpret weather events based on the Doppler effect. Typically, a transmitter emits radio waves at a specific frequency toward the sky from a weather station. The radio waves bounce off the clouds and precipitation and travel back to the weather station. The radio frequency of the waves reflected back to the station appears to decrease if the clouds or precipitation are moving...
Errors and Mistakes in Surveying01:19

Errors and Mistakes in Surveying

Errors and mistakes in surveying refer to inaccuracies in measurements and data recording. The errors are deviations from the actual value caused by human sensory limitations, equipment flaws, or environmental effects. These errors are typically unintentional and can result from the inherent imperfections in the instruments used, atmospheric conditions, or the observer’s inability to perceive exact measurements. On the other hand, mistakes are caused by the surveyor's lack of attention,...