Related Experiment Video
Updated: Aug 15, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients
Marc Feissel1, Julio Badie, Paolo G Merlani
1Intensive Care Unit, Centre Hospitalier, Belfort, France.
Objectives:
In septic patients with acute circulatory failure, reliable predictors of fluid responsiveness are needed at the bedside. We hypothesized that the respiratory change in pre-ejection period (DeltaPEP) would allow the prediction of changes in cardiac index following volume administration in mechanically ventilated septic patients.
Design:
Prospective clinical investigation.
Setting:
A ten-bed hospital intensive care unit.
Patients:
Patients admitted after septic shock equipped with an arterial catheter.
Interventions:
Pre-ejection period (PEP)--defined as the time interval between the beginning of the R wave on the electrocardiogram and the upstroke of the radial arterial pressure curve (PEPKT) or the pulse plethysmographic waveforms (PEPPLET)--and cardiac index (transthoracic echocardiography-Doppler) were determined before and after volume infusion of colloid (8 mL x kg). DeltaPEP (%) was defined as the difference between expiratory and inspiratory PEP divided by the mean of expiratory and inspiratory values. Respiratory changes in pulse pressure (DeltaPP) was also measured.
Measurements And Main Results:
: Twenty-two volume challenges were done in 20 deeply sedated patients. DeltaPEPKT, DeltaPEPPLET, and DeltaPP (measured in all patients) before volume expansion were correlated with cardiac index change after fluid challenge (r = .73, r = .67, and r = .70, respectively, p < .0001). Patients with a cardiac index increase induced by volume expansion > or = 15% and <15% were classified as responders and nonresponders, respectively. Receiver operating characteristic curves showed that the threshold DeltaPP value of 17% allowed discrimination between responder/nonresponder patients with a sensitivity of 85% and a specificity of 100%. For both DeltaPEPKT and DeltaPEPPLET, the best threshold value was 4% with a sensitivity-specificity of 92%-89% and 100%-67%, respectively.
Conclusions:
The present study found DeltaPEPKT and DeltaPEPPLET to be as accurate as DeltaPP in the prediction of fluid responsiveness in mechanically ventilated septic patients.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation I: Indication and Settings
Pulmonary Edema II: Pathophysiology