Related Experiment Video
Updated: Aug 15, 2026

A Novel Method: Super-selective Adrenal Venous Sampling
Published on: September 15, 2017
Relative adrenal insufficiency in patients with septic shock: comparison of low-dose and conventional corticotropin
Valérie Siraux1, Daniel De Backer, Gangadhar Yalavatti
1Department of Intensive Care, Erasme University Hospital, Brussels, Belgium.
Objective:
To compare a low-dose (1 microg) corticotropin stimulation test with the more standard (250 microg) test for the diagnosis of relative adrenal insufficiency.
Design:
Diagnostic study.
Setting:
Thirty-one-bed mixed medico-surgical department of intensive care.
Patients:
Forty-six consecutive patients with septic shock.
Interventions:
Corticotropin stimulation tests (low-dose test, 1 microg, and standard 250-microg test), performed consecutively at an interval >4 hrs.
Measurements And Main Results:
In each test, serum cortisol levels were measured before (T0) and 30 (T30), 60 (T60), and 90 (T90) mins after corticotropin injection. The maximal increase in cortisol (Deltamax) was calculated as the difference between T0 and the highest cortisol value at T30, T60, or T90 and considered as adequate if >9 microg/dL (250 nmol/L). Nonresponders to the low-dose test had a lower survival rate than responders to both tests (27 vs. 47%, p = .06; Kaplan Meier curves). Interestingly, nonresponders to high-dose test received hydrocortisone treatment and had a similar survival to responders. Multivariable logistic regression disclosed that the response to the combined low-dose test and high-dose test was an independent predictor of survival (odds ratio 28.91, 95% confidence interval 1.81-462.70, p = .017), whereas basal or maximal cortisol levels in both tests were not.
Conclusions:
The low-dose test identified a subgroup of patients in septic shock with inadequate adrenal reserve who had a worse outcome and would have been missed by the high-dose test. These patients may also benefit from glucocorticoid replacement therapy.
Related Concept Videos
Cushing Syndrome I: Introduction
Cushing Syndrome II: Pathophysiology
Adrenergic Agonists: Therapeutic Uses
Emergency and Intensive Care Unit (ICU) applications: Pressor agents increase blood pressure, heart rate, and contractility in shock and organ failure situations. Dopamine can induce vasodilation and stimulate adrenoceptors. Endogenous catecholamines are effective in treating cardiogenic shock. α2-agonists like clonidine can reverse anesthesia-induced hypertension.
Allergies and anaphylaxis:...
