1Servicio de Anestesiología, Reanimación y Terapéutica del Dolor, Hospital Clinico Universitario de Valladolid.
Objectives:
To report our experience during a learning period with the Ciaglia Blue Rhino (William Cook Europe) kit for percutaneous tracheotomy.
Patients And Methods:
This prospective, observational study included 38 adult patients who underwent elective placement of a percutaneous tracheostomy tube with the Ciaglia Blue Rhino introducer kit. The study was carried out from April 2002 to May 2003. The main variables analyzed were duration of the procedure, level of difficulty (easy, moderately difficult, difficult), and complications while the procedure was being performed.
Results:
The mean time of orotracheal intubation was 13.5 days (range, 2-28 days). The mean duration of the procedure was 12 minutes 36 seconds (range, 4 minutes 30 seconds-29 minutes; 95% confidence interval, 10 minutes 30 seconds-14 minutes 36 seconds). The procedure was rated easy in 60.5% of the cases, moderately difficult in 31.6%, and difficult in 7.9%. Some form of complication occurred in 28 patients (73.6%), the most common being puncture of the orotracheal tube (28.9%) and slight bleeding (26.3%). Two patients (5.2%) died, from massive hemorrhage in 1 case and pneumothorax in the other.
Conclusions:
The Ciaglia Blue Rhino technique for percutaneous tracheotomy is useful, rapid, and easy but not free of risk. There is a learning curve that calls for caution and an experienced physician to perform the maneuvers, given that potentially fatal complications can occur.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques