A multicentered comparison of measurements obtained with microtip and external water pressure transducers
Andrew F Hundley1, Morton B Brown, Linda Brubaker
1Division of Female Pelvic Medicine and Reconstructive Pelvic Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
Abstract:
This study compared simultaneous intravesical pressure readings obtained with catheter-mounted microtip transducers and external water pressure transducer catheters during filling cystometry. Women undergoing multichannel urodynamic testing were randomly assigned to one of three groups: two microtip catheters, two external water pressure transducer catheters, or one of each type. Intravesical pressure was measured simultaneously for each transducer combination in each subject for minimal and maximal Valsalva effort and minimal, moderate, and maximal cough effort at two sequential bladder volumes (150 and 300 ml). Paired t tests were used to compare the means of the intravesical pressure obtained by the two types of catheters. The largest mean differences were observed when comparing microtip and water pressure transducers. Correlations of maximum pressure were consistently high between two microtip transducers and two water pressure transducers but lower for the microtip-water combination. Excellent reproducibility was demonstrated with transducers of similar types for intravesical pressures recorded during Valsalva and cough in women without prolapse. However, considerable variability was seen in pressures recorded by different transducers, particularly dependent on the water catheter manufacturer, indicating that intravesical pressure recordings from microtip and water-based systems are not interchangeable.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pipe Flowrate Measurement
The orifice meter is a simple,...