Related Experiment Video
Updated: Aug 14, 2026

Endobronchial Ultrasound-guided Intratumoral Injection of Cisplatin for the Treatment of Isolated Mediastinal Recurrence of Lung Cancer
Published on: February 12, 2017
[Evaluation of response to neoadjuvant chemotherapy using breast scintigraphy in breast cancer]
José M Baena-Cañada1, Francisca Partida-Palma, María J Palomo-González
1Unidad Clínica de Patología Mamaria, Hospital Universitario Puerta del Mar, Cádiz, Spain. josem.baena.sspa@juntadeandalucia.es
Background And Objective:
We sought to evaluate the usefulness of Tc-99m-sestamibi breast scintigraphy in predicting neoadjuvant chemotherapy response in patients with breast cancer.
Patients And Method:
In 50 consecutive patients with breast cancer stages II and III, physical examination, mammography and scintimammography were performed before and after the administration of neoadjuvant chemotherapy. The 3 assessments were compared for predictive value using a pathological response as reference. Values derived from visual assessment of the scintimammography, a quantitative tumor/background index, and isotope clearance were compared to the immunohistochemical expression of P-glycoprotein, vascular endothelial growth factor (VEGF) and microvessel density (CD31) in relation to neoadjuvant chemotherapy response.
Results:
Macroscopic response was obtained in 10 cases (20%). Sensitivity was 86.5% (95% confidence interval [CI], 70.4-94.9) for the physical examination, 83.3% (95% CI, 68-92.5) for the mammography and 76.5% (95% CI, 58.4-88.6) for the scintimammography. Specificity was 38.5% (95% CI, 15.1-67.7) for the physical examination, 42.9% (95% CI, 11.8-79.8) for the mammography and 8.3% (95% CI, 0.4-40.2) for the scintimammography. There were no statistically significant differences in isotope uptake and clearance with regard to response nor in relation to levels of expression of P-glycoprotein, VEGF and microvessel density.
Conclusions:
Breast scintigraphy with Tc-99m-sestamibi is not useful in predicting the response to neoadjuvant chemotherapy in breast cancer. Traditional physical examination and mammography are more effective. Isotope uptake and clearance do not predict response and there is not an effective in vivo measurement of chemo-resistance or tumor angiogenesis.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET