Related Experiment Video
Updated: Aug 14, 2026

Electrostatic Method to Remove Particulate Organic Matter from Soil
Published on: February 10, 2021
Simultaneous removal of organic compounds and heavy metals from soils by electrokinetic remediation with a modified
Kranti Maturi1, Krishna R Reddy
1Department of Civil and Materials Engineering, University of Illinois at Chicago, 2095 Engineering Research Facility, 842 West Taylor Street, Chicago, IL 60607, USA.
Abstract:
Thousands of sites are contaminated with both heavy metals and organic compounds and these sites pose a major threat to public health and the environment. Previous studies have shown that electrokinetic remediation has potential to remove heavy metals and organic compounds when they exist individually in low permeability soils. This paper presents the feasibility of using cyclodextrins in electrokinetic remediation for the simultaneous removal of heavy metals and polycyclic aromatic hydrocarbons (PAHs) from low permeability soils. Kaolin was selected as a model low permeability soil and it was spiked with phenanthrene as well as nickel at concentrations of 500 mg kg-1 each to simulate typical mixed field contamination. Bench-scale electrokinetic experiments were conducted using hydroxypropyl beta-cyclodextrin (HPCD) at low (1%) and high (10%) concentrations and using deionized water in control test. A periodic voltage gradient of 2VDC cm-1 (with 5 d on and 2 d off) was applied to all the tests, and 0.01 M NaOH was added during the experiments to maintain neutral pH conditions at anode. In all tests, nickel migrated as Ni2+ ions towards the cathode and most of it was precipitated as Ni(OH)2 within the soil close to the cathode due to high pH condition generated by electrolysis reaction. The solubility of phenanthrene in the flushing solution and the amount of electroosmotic flow controlled the migration and removal of phenanthrene in all the tests. Even though high flow was generated in tests using deionized water and 1% HPCD, migration and removal of phenanthrene was low due to low solubility of phenanthrene in these solutions. The test with 10% HPCD solution showed higher solubility of phenanthrene which caused it migrate towards the cathode, but further migration and removal was retarded due to reduced electric current and electroosmotic flow. Approximately one pore volume of flushing resulted in approximately 50% removal of phenanthrene from the soil near the anode. Sustained higher electroosmotic flow with higher concentration cyclodextrin and maintaining low soil pH near cathode should be investigated to increase removal efficiency of both phenanthrene and nickel.
More Related Videos
05:52Resource Recycling of Red Soil to Synthesize Fe2O3/FAU-type Zeolite Composite Material for Heavy Metal Removal
Published on: June 2, 2022
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Extraction: Advanced Methods
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Microbial Bioremediation of Pesticides
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Bioremediation
Electrodeposition
Electrodeposition can...