Related Experiment Video
Updated: Aug 14, 2026

Modified Most Probable Number Assay to Quantify Salmonella in Raw and Ready-to-Cook Chicken Products
Published on: January 31, 2025
Quantification of Listeria monocytogenes in salads by real time quantitative PCR
H Berrada1, J M Soriano, Y Picó
1University of Valencia, Faculty of Pharmacy, Laboratory of Bromatology and Toxicology, Burjassot, Valencia, Spain.
Abstract:
A real time quantitative PCR (RTQ-PCR) was carried out purifying DNA extracts of Listeria monocytogenes using a High Pure Listeria Sample Preparation Kit and quantifying in a LightCycler system with hybridisation probes. A standard curve was constructed with serial dilutions. A range linear relationship, from 10 to 10(5)L. monocytogenes colony forming units (CFU), was observed between threshold cycle (Ct) and logarithmic concentration of the serial dilutions. The assay was linear in a range from 10 to 10(5)L. monocytogenes CFU and the coefficient of determination (r2) was >0.98. RTQ-PCR presented an efficiency of >85%. The accuracy of the PCR-based assay, expressed as % bias, ranged from 9% to 26% and the precision, expressed as % CV, ranged 9-22%. Intraday and interday variabilities were studied at 10(2) CFU/g and resulted in 12% and 14%, respectively. The proposed RTQ-PCR method and classical cultural methods were applied to analyse 77 salads from restaurants in Valencia (Spain). All culture positive samples were also RTQ-PCR positive.