Development of characteristic equations and robust stability analysis for MIMO move suppressed and shifted DMC
R Dubay1, G Kember, C V Lakshminarayan
1Department of Mechanical Engineering, University of New Brunswick, Fredericton, NB, Canada. dubayr@unb.ca
Abstract:
Discrete-time controller and closed-loop transfer functions were developed for move suppressed lambda and the recently formulated m-shifted multiple-input-multiple-output (MIMO) dynamic matrix control (DMC). Using these transfer functions, robust analyses were conducted for MIMO plants by varying corresponding delay and gain ratios of the system. In all instances, robust plots indicate that the shifted DMC is less sensitive and hence more robust to variations in the plant parameters than move suppressed DMC. It was shown that the design of these MIMO DMC controllers depends on the plant closed-loop performance and overall stability, since the selection of lambda and m directly influences the plant robustness and closed-loop dynamics.
Related Concept Videos
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's response.
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system.
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Mason's Rule
Loop gain is determined by identifying and tracing a path from a node back to itself. This involves computing the product of branch gains along the loop. Each loop's gain is crucial for further...
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be calculated...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...