Related Experiment Video
Updated: Aug 14, 2026

International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Tension pneumothorax complicating autologous "blood patch" pleurodesis
1Department of Cardiology, Manchester Royal Infirmary, UK.
Abstract:
Autologous "blood patching" has been used successfully for the treatment of persistent air leak in patients with spontaneous secondary pneumothorax. The case history is presented of a 19 year old woman with cystic fibrosis who developed tension pneumothorax following this procedure, with rapid clinical deterioration until the obstruction was cleared. To avoid this potentially fatal complication we recommend that "blood patch" pleurodesis be performed only through large bore intercostal catheters, that blood is rapidly transferred into the catheter tubing, a sterile saline flush and full resuscitation equipment is available, and the operator is skilled in the management of tension pneumothorax.
Related Concept Videos
Pneumothorax II: Pathophysiology
Pneumothorax-II
Clinical Manifestations:
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Pleura of the Lungs
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's criteria,...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...