Related Experiment Video
Updated: Aug 14, 2026

Primary Outcome Assessment in a Pig Model of Acute Myocardial Infarction
Published on: October 14, 2016
Noninvasive Doppler-derived myocardial performance index in rats with myocardial infarction: validation and
David Jegger1, Xavier Jeanrenaud, Mohammad Nasratullah
1Laboratory of Hemodynamics and Cardiovascular Technology, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland. David.Jegger@epfl.ch
Abstract:
The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance catheter (CC). Sprague-Dawley rats with left anterior descending coronary artery ligation (MI group, n = 9) were compared with a sham-operated control group (n = 10) without MI. Transthoracic echocardiography (TTE) was performed every 2 wk over an 8-wk period, after which classic TTE parameters, especially MPI and LVFS/MPI, were compared with invasive indexes obtained by using a CC. Serial TTE data showed significant alterations in the majority of the noninvasive functional and structural parameters (classic and novel) studied in the presence of MI. Both MPI and LVFS/MPI significantly (P < 0.05 for all reported values) correlated with body weight (r = -0.58 and 0.76 for MPI and LVFS/MPI, respectively), preload recruitable stroke work (r = -0.61 and 0.63), LV end-diastolic pressure (LVEDP) (r = 0.82 and -0.80), end-diastolic volume (r = 0.61 and -0.58), and end-systolic volume (r = 0.46 and -0.48). Forward stepwise linear regression analysis revealed that, of all variables tested, LVEDP was the only independent determinant of MPI (r = 0.84) and LVFS/MPI (r = 0.83). We conclude that MPI and LVFS/MPI correlate strongly and better than the classic noninvasive TTE parameters with established, invasively assessed indexes of contractility, preload, and volumetry. These findings support the use of these two new noninvasive indexes for long-term analysis of the post-MI LV remodeling.
Insights
New echocardiographic indexes, myocardial performance index (MPI) and LVFS/MPI, accurately track long-term heart function after myocardial infarction (MI) in rats. These noninvasive measures correlate well with invasive assessments, offering a reliable tool for heart failure research.
Area of Science:
- Cardiology
- Animal Models
- Heart Failure Research
Background:
- Rodent models are crucial for studying heart failure post-myocardial infarction (MI).
- Long-term validation of noninvasive echocardiographic parameters like myocardial performance index (MPI) against invasive measures is lacking.
Purpose of the Study:
- To validate novel echocardiographic indexes, MPI and LVFS/MPI, against invasive hemodynamic measurements in a long-term rodent model of MI.
- To assess the utility of these noninvasive parameters for tracking left ventricular (LV) remodeling post-MI.
Main Methods:
- Sprague-Dawley rats underwent coronary artery ligation (MI group) or sham operation.
- Transthoracic echocardiography (TTE) was performed bi-weekly for 8 weeks.
- TTE parameters, including MPI and LVFS/MPI, were compared with invasive conductance catheter (CC) data.
Main Results:
- Serial TTE revealed significant alterations in LV function and structure in the MI group.
- MPI and LVFS/MPI showed strong correlations with invasive indexes of contractility, preload, and volume (e.g., LVEDP, end-diastolic volume).
- LV end-diastolic pressure (LVEDP) was identified as the sole independent determinant for both MPI and LVFS/MPI.
Conclusions:
- MPI and LVFS/MPI are reliable noninvasive indexes for long-term assessment of post-MI LV remodeling.
- These novel echocardiographic parameters offer superior correlation with invasive assessments compared to traditional TTE metrics.
- Supports the use of MPI and LVFS/MPI in future heart failure studies utilizing rodent models.