Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
The chemometric resolution and quantification of overlapped peaks form comprehensive two-dimensional liquid
Carlos G Fraga1, Cynthia A Corley
1Department of Chemistry, 2355 Fairchild Dr., Suite 2N225, United States Air Force Academy, CO 80840-6230, USA. carlos.fraga@usafa.af.mil
Abstract:
The chemometric resolution and quantification of overlapped peaks from comprehensive two-dimensional (2D) liquid chromatography (LCxLC) data are demonstrated. The LCxLC data is produced from an in-house LCxLC analyzer that couples an anion-exchange column via a multi-port valve with a reversed-phase column connected to a UV absorbance detector. Three test mixtures, each containing a target analyte, are subjected to partial LCxLC separations to simulate likely cases of signal overlap. The resulting unresolved target-analyte signals are then analyzed by the standard-addition method and two chemometric methods. The LCxLC analyses of a test mixture and its corresponding standard-addition mixture results in two data matrices, one for each mixture. The stacking of these two data matrices produces a data structure that can then be analyzed by trilinear chemometric methods. One method, the generalized rank annihilation method (GRAM), uses a non-iterative eigenvalue-based approach to mathematically resolve overlapped trilinear signals. The other method, parallel factor analysis (PARAFAC), uses an iterative approach to resolve trilinear signals by the optimization of initial estimates using alternating least squares and signal constraints. In this paper, GRAM followed by PARAFAC analysis is shown to produce better qualitative and quantitative results than using each method separately. For instance, for all three test mixtures, the GRAM-PARAFAC approach improved quantitative accuracy by at least a factor of 4 and quantitative precision by more than 2 when compared to GRAM alone. This paper also introduces a new means of correcting run-to-run retention time shifts in comprehensive 2D chromatographic data.
More Related Videos
07:10Untargeted Liquid Chromatography-Mass Spectrometry-Based Metabolomics Analysis of Wheat Grain
Published on: March 13, 2020
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...