Related Experiment Video
Updated: Aug 14, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Central venous catheter colonization in critically ill patients: a prospective, randomized, controlled study
Martin W Dünser1, Andreas J Mayr, Guido Hinterberger
1*Division of General and Surgical Intensive Care Medicine, Department of Anesthesia and Critical Care Medicine, †Institute for Hospital Hygienics and Social Medicine, and ‡Institute for Medical Biostatistics, Innsbruck Medical University; §Department of Anesthesia and Critical Care Medicine, Krankenhaus der Barmherzigen Schwestern, Ried I. Innkreis, Austria.
Abstract:
In this prospective, randomized, controlled, unblinded study, we compared colonization rates of a standard, unimpregnated central venous catheter (CVC) with rates for silver-coated and chlorhexidine-silversulfadiazine (CH-SS)-impregnated CVC. Patient characteristics, CVC insertion site, indwelling time, and colonization detected by semiquantitative and quantitative microbiologic techniques were documented. Two-hundred-seventy-five critically ill patients were included into the study protocol. One-hundred-sixty standard, 160 silver (S)-coated, and 165 externally impregnated CH-SS CVC were inserted. There was a significant difference in CVC colonization rates among study groups (P = 0.029). There was no difference in the colonization rate and the colonization per 1000 catheter days between standard and S-coated (P = 0.564; P = 0.24) or CH-SS-coated CVC (P= 0.795; P = 0.639). When comparing antiseptic CVC with each other, colonization rates were significantly less with CH-SS-impregnated than with S-coated CVC (16.9% versus 7.3%; P = 0.01; 18.2 versus 7.5 of 1000 catheter days; P = 0.003; relative risk, 0.43; 95% confidence interval, 0.21-0.85). Whereas standard and S-coated CVC were first colonized 2 and 3 days after insertion, respectively, CH-SS CVC were first colonized only after 7 days. In conclusion, antiseptic-impregnated CVC could not prevent catheter colonization when compared with standard polyurethane catheters in a critical care setting with infrequent catheter colonization rates and CVC left in place for >10 days.
Related Concept Videos
Hand hygiene
Hand washing...
Endocarditis IV: Nursing Management
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...

