Maria Schuster1, Frank Rosanowski, Raphael Schwarz
1Department of Phoniatrics and Pedaudiology, University Hospital, Erlangen, Germany. maria.schuster@phoni.imed.uni-erlangen.de
Objective:
To evaluate the vibration pattern of the substitute voice generator of patients who have undergone laryngectomy. For automatic quantification of the oscillations of the pharyngoesophageal (PE) segments, image processing of digital high-speed video sequences is applied.
Design:
Physiologic analysis.
Setting:
An acute care hospital.
Patients:
Endoscopic recordings were taken of 10 men who underwent laryngectomy (mean +/- SD age, 61.5 +/- 5.2 years) during sustained phonation of a vowel using a 90 degree endoscope coupled to a high-speed camera.
Main Outcome Measures:
An image-processing algorithm was developed to automatically define the pseudoglottis in each recording and track its movements.
Results:
The clinical assessment of the high-speed technique for the endoscopic examination of the substitute voice generator yields the following results. The forms and oscillation characteristics of the pseudoglottides varied considerably: 3 pseudoglottides were circular, 6 were split shaped, and 1 was triangle shaped. A quasi-periodic opening and closing were observed and automatically detected by the described algorithm in each recording independently from quality of the recording and from morphologic and oscillation characteristics of the PE segment. The frequencies of the extracted oscillations of the pseudoglottides correspond to the structure of the acoustic signals.
Conclusions:
Automatic image processing of PE segments derived from high-speed endoscopic recordings enables the detection and quantification of the substitute voice generator's oscillations in high temporal resolution. These data directly prove that the detected pseudoglottis is the source of the substitute voice. Close relations between substitute voice and functional properties of the PE segment exist. In the future, these data will be interpreted by applying biomechanical models of the PE segment. Presumably, results may help to optimize surgical and adaptive procedures for specific substitute voice restoration.
Related Concept Videos
Larynx
Anatomy of the Larynx
The larynx consists of various components, including cartilage, muscles, and vocal cords. Its structure includes three large unpaired cartilages—the thyroid, cricoid, and epiglottis—and three smaller paired cartilages—the arytenoids, corniculates, and...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.