Abstract:
A biocompatible, sustained-release subretinal drug-delivery platform was developed to overcome the therapeutic accessibility limitations of current retinal disease treatments. The prototype implants were fabricated by coating nitinol, poly(methyl methacrylate) or chromic gut core filaments, with a drug-eluting polymer matrix. The polymer coatings are manufactured and coated by SurModics. The coating is a mixture of poly(butyl methacrylate) and poly(ethylene-co-vinyl acetate). The drug is either triamcinolone acetonide or sirolimus. The rods were successfully implanted into the subretinal space of 20/24 rabbits. Four rabbits were lost to early surgery from a dysfunctional infusion line and hemorrhage. No serious complications were observed during the 4-week follow-up period. Slight conjunctival redness was reported in all rabbits by 1-day follow-up, but the redness had subsided by the following week. Intraocular lens touch occurred in six rabbits during the implantations; of these, four had a lensectomy at the time of surgery, and the remaining two developed cataract. Corneal edema developed in three rabbits by 1-week follow-up, but subsided within 2 weeks. Initial observations of the implantation and elution characteristics revealed that the implants are well tolerated by the retinal tissue and that the implant can elute triamcinolone acetonide for a period of at least 4 weeks without eliciting an inflammatory response or complications. There were adverse clinical indications with the sirolimus-loaded implants at the delivered dose. Device retrieval required an uncomplicated surgical procedure, and revealed no associated or adherent tissue. Implant drug content analysis and opacity changes to the polymer matrix coating following retrieval demonstrated the sustained elution of the drug.
Related Concept Videos
Intrauterine Drug Delivery Systems
Ophthalmic Drug Delivery Systems
Modified-Release Drug Delivery Systems: Site-Targeted
Modified-Release Drug Delivery Systems: Rate-Programmed II
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Modified-Release Drug Delivery Systems: Classification