Related Experiment Video
Updated: Aug 14, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Colorectal polyps: detection with dark-lumen MR colonography versus conventional colonoscopy
Dirk Hartmann1, Boris Bassler, Dieter Schilling
1Department of Medicine C (Gastroenterology), Hospital Ludwigshafen, Academic Teaching Hospital of Johannes-Gutenberg-University of Mainz, Bremserstrasse 79, 67063 Ludwigshafen am Rhein, Germany.
Purpose:
To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps.
Materials And Methods:
Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T MR unit with patients in the prone position. A T1-weighted three-dimensional volumetric interpolated breath-hold sequence was performed before and 75 seconds after intravenous administration of 0.2 mmol gadobenate dimeglumine per kilogram of body weight. Results of MR colonography were analyzed on a per-polyp and per-patient basis. Findings at colonoscopy were used as the reference for determining accuracy, sensitivity, specificity, and positive and negative predictive values of MR colonography.
Results:
Of 100 patients recruited for study, 92 (52 men, 40 women; mean age, 61.5 years +/- 14.5; range, 25-82 years) underwent complete MR and conventional colonoscopy examinations. Forty-three of the 92 patients (47%) had normal findings at conventional colonoscopy. In the other 49 patients (53%), conventional colonoscopy depicted 107 polyps (82 adenomas, 25 hyperplastic polyps) and seven carcinomas. At per-polyp analysis, sensitivity of MR colonography in the detection of adenomatous polyps was 100% for polyps at least 10 mm in diameter and 84.2% for polyps 6-9 mm in diameter. At per-patient analysis, the accuracy of MR colonography was 93.1% (sensitivity, 89%; specificity, 96%) if detection of adenomatous polyps of all sizes was considered.
Conclusion:
Dark-lumen MR colonography is a promising modality with high accuracy for detecting colorectal polyps larger than 5 mm in diameter.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Endoscopic Procedures III: Video Capsule Endoscopy