Related Experiment Video
Updated: Aug 2, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Myocardial systolic strain is decreased after aortic valve replacement in patients with aortic insufficiency
Benjamin J Pomerantz1, Jason R Wollmuth, Marc D Krock
1Division of Cardiothoracic Surgery, Department of Surgery, Washington University, St. Louis, Missouri, USA.
Background:
Left ventricular three-dimensional nonlinear systolic strain determinations have potential to detect small decrements in ventricular function in patients with aortic insufficiency before and after aortic valve replacement.
Methods:
Magnetic resonance imaging with tissue-tagging was performed on 42 normal volunteers and 14 patients with chronic aortic insufficiency both before and 28 +/- 11 months after aortic valve replacement. Preoperative and postoperative left ventricular volume, dimensions and ejection fraction were determined for all subjects. Left ventricular systolic radial, circumferential, longitudinal, and minimum principal strain were calculated for six left ventricular regions.
Results:
After aortic valve replacement, left ventricular volume and dimensions decreased significantly (p < 0.001) and ejection fraction increased nonsignificantly (p = 0.096). Strain values in preoperative aortic insufficiency patients did not differ significantly from controls. At an average of 28 +/- 11 months postoperatively, however, regional three-dimensional minimum principal and longitudinal strain was decreased in all six ventricular regions as well as globally (p < 0.03) compared with normal control values. Circumferential strain was significantly decreased globally and in all but two regions (p < 0.03).
Conclusions:
These magnetic resonance imaging-based techniques are sensitive enough to detect a previously unrecognized, significant decrease in both global and regional three-dimensional left ventricular systolic strain 2 years after aortic valve replacement for minimally symptomatic chronic aortic insufficiency despite improvement in ejection fraction and a decrease in left ventricular size. The reasons for a significant decline in left ventricular systolic strain after successful aortic valve replacement in minimally symptomatic chronic aortic insufficiency patients are not clear and warrant further investigation.
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Mitral Stenosis I: Introduction
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management