Arsenic speciation in human hair: a new perspective for epidemiological assessment in chronic arsenicism

Jorge Yáñez1, Vladimir Fierro, Hector Mansilla

  • 1Department of Analytical & Inorganic Chemistry, Faculty of Chemical Sciences, University of Concepción, Concepción, P.O. Box 160-C, Chile.

Related Concept Videos

Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Toxicity Testing in Animals01:23

Toxicity Testing in Animals

Toxicity tests in animals are grounded on two main assumptions: first, the effects observed in laboratory animals can be extrapolated to humans, especially when adjusted for body surface area; second, high-dose exposure in animals is essential to identify potential human hazards from lower doses. This is based on the quantal dose-response concept, which faces the challenge of extrapolating results from relatively few test animals to much larger human populations. For example, a 0.01% incidence...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...