Infrared-monitored cold response in the assessment of Raynaud's phenomenon
J Foerster1, S Wittstock, S Fleischanderl
1Clinic for Dermatology, Charité, Berlin, Germany. john.foerster@charite.de
Background:
Evaluation of treatments for Raynaud's phenomenon (RP) requires objective response parameters in addition to clinical activity scores. Thermographic monitoring of fingertip re-warming after cold challenge has been widely used but usually requires sophisticated equipment. We have previously shown that fingertip re-warming after cold challenge follows a first-order transient response curve that can be described by a single variable, designated tau.
Objectives:
Here, we describe a novel device termed a duosensor, which records the tau value upon cold challenge in an automated manner.
Methods:
We determined tau values in healthy probands, patients with primary or secondary RP associated with autoimmune disease and patients with scleroderma-associated RP following cold challenge, to determine assay variability, sensitivity and specificity.
Results:
Duosensor-based thermography exhibited low intraindividual variability in healthy probands. As expected, tau values in RP patients were significantly increased compared with controls (8.08 +/- 3.65 min vs. 3.23 +/- 1.65 min). The duosensor-determined tau value yielded a specificity of 94.6% and predictive value of 95.3% for the presence of RP in a retrospective analysis of 139 patients. Furthermore, in a cohort of scleroderma patients with RP, patient self-assessment of RP severity correlated with tau values.
Conclusions:
Taken together, the present data suggest that tau value determination provides a suitable outcome measure for clinical studies of novel RP treatments. As the duosensor is a simple stand-alone device requiring no supporting equipment and minimal personnel attention, it should allow RP activity monitoring even in clinical settings with minimal technical infrastructure.
Related Concept Videos
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...