The nature of residual cost in regular switch response factors

Emilio G Milán1, Antonio González, Daniel Sanabria

  • 1Departamento de Psicología Experimental y Fisiología de la Conducta, University of Granada, Campus Cartuja s/n, 18071 Granada, Spain. ogomez@ugr.es

Acta Psychologica
|November 29, 2005
PubMed

Related Concept Videos

RC Circuit with Source01:15

RC Circuit with Source

When a DC source is abruptly applied to an RC (Resistor-Capacitor) circuit, the voltage can be represented as a unit step function. The voltage across the capacitor, known as the step response, characterizes how the circuit reacts to this sudden change in input.
Due to the inherent properties of a capacitor, its voltage cannot change instantaneously. This means that immediately after the switch is closed, the capacitor's voltage remains the same as it was just before the switch was closed.
By...
RL Circuit with Source01:14

RL Circuit with Source

When an RL (Resistor-Inductor) circuit is connected to a DC source, the complete response of the circuit can be divided into two parts: the transient response and the steady-state response.
The transient response of the circuit is its temporary reaction to the sudden application of the DC source. This response is characterized by a current that exponentially decays to zero as time approaches infinity. During this transitional period, the inductor behaves like a short circuit, causing the source...
Types of Responses of Series RLC Circuits01:11

Types of Responses of Series RLC Circuits

A second-order differential equation characterizes a source-free series RLC circuit, marking its distinct mathematical representation. The complete solution of this equation is a blend of two unique solutions, each linked to the circuit's roots expressed in terms of the damping factor and resonant frequency.
Parallel RLC Circuits01:14

Parallel RLC Circuits

Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
Design Example: Frog Muscle Response01:14

Design Example: Frog Muscle Response

A student is tasked to work on an intriguing experiment involving an RL (Resistor-Inductor) circuit to study the muscle response of a frog's leg to electrical stimulation. The RL circuit plays a crucial role in this experiment, providing the means to control and measure the electrical impulses that trigger muscle contraction.
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short circuit,...
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.