Related Experiment Video
Updated: Aug 4, 2026

10:10
Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research
Published on: November 2, 2018
[Contrast sensitivity to intraocular lens TECNIS Z-9000]
A Lanzagorta-Aresti1, E Palacios-Pozo, J F Taboada-Esteve
1Hospital Universitario La Fe, Valencia, España. oftaitor@hotmail.com
Archivos De La Sociedad Espanola De Oftalmologia
|November 29, 2005
Summary
The TECNIS Z-9000 intraocular lens significantly improves contrast sensitivity, enhancing visual function quality. This study compared its performance against other intraocular lenses.
Area of Science:
- Ophthalmology
- Biomedical Engineering
Background:
- Intraocular lenses (IOLs) are crucial for vision restoration after cataract surgery.
- Assessing contrast sensitivity is vital for evaluating IOL performance and visual quality.
Purpose of the Study:
- To evaluate the contrast sensitivity provided by the TECNIS Z-9000 intraocular lens (IOL).
- To compare the TECNIS Z-9000 IOL's contrast sensitivity against other IOLs.
Main Methods:
- A comparative study involving 18 patients implanted with the TECNIS Z-9000 IOL in one eye and a different IOL in the contralateral eye.
- Contrast sensitivity was measured under mesopic and photopic conditions using the Vision Contrast Test System (VCTS).
Main Results:
- Improved contrast sensitivity was observed at low and medium spatial frequencies after TECNIS Z-9000 IOL implantation, though not reaching statistical significance.
- Significant improvements in contrast sensitivity were noted at high spatial frequencies, directly correlating with enhanced visual function quality.
Conclusions:
- The TECNIS Z-9000 IOL, featuring a modified anterior surface, demonstrates a significant enhancement in contrast sensitivity.
- This improvement translates to a practical increase in the quality of visual function for patients.
Related Concept Videos
Open Angle Glaucoma: Treatment
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...