Related Experiment Video
Updated: Aug 14, 2026

A Multimodal Wide-Field Fourier-Transform Raman Microscope
Published on: December 30, 2025
Partial least squares based decomposition of five spectrally overlapping factors
Natalie Pomerleau-Dalcourt1, Robert Weersink, Lothar Lilge
1Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
Abstract:
The development of a multi-sensory fiber-optic based fluence rate probe (MSP) for light monitoring and dosimetry during photodynamic therapy (PDT) created the need for a robust multivariate signal analysis algorithm capable of quantifying the intensity of five component spectra, representing the sensors, which display a large degree of spectral overlap. Partial least squares (PLS) analysis, as an option for such an analysis algorithm, was evaluated through simulations in the presence of three types of noise, which experimentally may limit the accuracy of PLS quantification of component spectra contributions. Random, or white noise, background was varied over a range of 0-15% relative intensity. A non-random (Gaussian) background vector was simulated, as an experimentally relevant spectral interferent, over a range of 0-7% relative intensity. Spectral variation was modeled by a spectral shift of +/-1-5 nm. Procedures for selecting preferred combinations of fluorophores, with minimum possible spectral overlap, were developed. To illustrate the importance of this selection process, PLS performance results were compared for two possible combinations of five fluorophores, as well as for the combination of three fluorophores currently in experimental use with MSPs. Experimentally anticipated worst-case quantifications were identified for all three types of simulated noise (5% random background, 0.5% Gaussian background, and +/-2 nm spectral shift). The effects of single and combined types of noise were evaluated by independently varying each type of simulated noise over the experimentally relevant range. The mean percentage error in determining the fluorophore contributions and hence quantification of the fluence rate were compared with the required performance standard of better than 10% error for optical power meters in medical use. The PLS algorithm provided an accuracy of 7 +/- 2% for five fluorophores and 3.3 +/- 0.8% for three fluorophores, indicating that PLS is an appropriate choice for this application.
More Related Videos
07:11ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
08:49Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
Published on: December 1, 2023
Related Concept Videos
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an organic...
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...