Initial clinical experience with regadenoson, a novel selective A2A agonist for pharmacologic stress single-photon
Robert C Hendel1, Timothy M Bateman, Manuel D Cerqueira
1Rush University Medical Center, Chicago, Illinois, USA. rhendel@midwestheart.org
Objectives:
Regadenoson, a selective A2A adenosine receptor agonist, was evaluated for tolerability and effectiveness as a pharmacological stress agent for detecting reversible myocardial hypoperfusion when combined with single-photon emission computed tomography (SPECT).
Background:
Adenosine and dipyridamole are nonselective adenosine agonists currently used as pharmacologic stressors. Despite proven safety, these agents often cause undesirable side effects and require a continuous infusion.
Methods:
This Phase II, multicenter, open-label trial was conducted in 36 patients who had demonstrated ischemia on a 6-min adenosine SPECT imaging study within the previous 2 to 46 days. Patients received regadenoson as a rapid intravenous bolus dose of 400 microg (n = 18) or 500 microg (n = 18). The radiopharmaceutical was then delivered within one minute. The SPECT images were acquired in a standard manner and uniformly processed at a central laboratory. Regadenoson and adenosine studies were presented in random order and interpreted blindly with a 17-segment model by three observers. Additionally, quantitative analysis was performed with 4D-MSPECT software (University of Michigan, Ann Arbor, Michigan).
Results:
Overall agreement for the presence of reversible hypoperfusion was 86%. The 400-mug dose was better tolerated. Overall, regadenoson was well-tolerated; side effects (e.g., chest discomfort, flushing, dyspnea) were generally mild in severity and self-limiting. High-grade atrioventricular block and bronchospasm were not observed.
Conclusions:
Regadenoson is well-tolerated and seems as effective as adenosine for detecting and quantifying the extent of hypoperfusion observed with SPECT perfusion imaging. Phase III clinical trials are now underway, given the promise of regadenoson's reduced side effects and simplicity of bolus administration.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...