Infection control guidelines for the cardiac catheterization laboratory: society guidelines revisited
Charles E Chambers1, Michael D Eisenhauer, Lynn B McNicol
1Hershey Medical Center, 500 University Drive H047, Division of Cardiology Hershey, PA 17033, USA. cchambers@psu.edu
Insights
Sterile precautions in cardiac catheterization labs are crucial, especially with increased device implantation. Updated guidelines emphasize hand washing, personal protective equipment, and environmental controls to reduce patient infection rates.
Area of Science:
- Cardiology
- Infectious Disease Prevention
- Healthcare Policy
Background:
- Cardiac catheterization has evolved from diagnostic procedures requiring strict sterile cutdowns to complex interventional suites.
- The increased use of percutaneous access and device implantation (e.g., stents, closure devices) has changed laboratory practices.
- Current sterile precautions often fall short despite frequent device implantation, necessitating updated guidelines.
Purpose of the Study:
- To revise and update infection control guidelines for cardiac catheterization laboratories.
- To address the challenges posed by the shift towards interventional procedures and device implantation.
- To provide specific recommendations for patient, personnel, and environmental protection.
Main Methods:
- Review of historical practices and evolution of cardiac catheterization procedures.
- Analysis of reasons for the decline in adherence to sterile techniques.
- Incorporation of recommendations from a Society of Cardiovascular Angiography and Interventions (SCAI) survey.
- Integration of relevant Centers for Disease Control and Prevention (CDC) recommendations.
Main Results:
- Hand washing is identified as the most critical infection prevention procedure.
- Personal protective equipment (caps, masks, gowns, gloves, eye wear) is essential for maintaining a sterile field and protecting personnel.
- Environmental controls, including cleaning, traffic limitation, and ventilation, are vital.
- Hepatitis B vaccination is recommended for all personnel.
Conclusions:
- Updated guidelines are necessary to reflect current interventional practices in cardiac catheterization laboratories.
- Strict adherence to sterile techniques, including hand hygiene and appropriate use of personal protective equipment, can significantly decrease patient infection rates.
- Comprehensive infection control strategies encompassing patients, personnel, and the laboratory environment are essential.
Abstract:
In the early years of diagnostic cardiac catheterization, strict sterile precautions were required for cutdown procedures. Thirteen years ago, when the original guidelines were written, the brachial arteriotomy was still frequently utilized, femoral closure devices were uncommon, "implantables," such as intracoronary stents and PFO/ASD closure devices, were in their infancy, and percutaneous valve replacement was not a consideration. In 2005, the cardiac catheterization laboratory is a complex interventional suite with percutaneous access routine and device implantation standard. Despite frequent device implantation, strict sterile precautions are often not observed. Reasons for this include a decline in brachial artery cutdown, limited postprocedure follow-up with few reported infections, limited use of hats and masks in televised cases, and lack of current guidelines. Proper sterile technique has the potential to decrease the patient infection rate. Hand washing remains the most important procedure for preventing infections. Caps, masks, gowns, and gloves help to protect the patient by maintaining a sterile field. Protection of personnel may be accomplished by proper gowning, gloving, and eye wear, disposal of contaminated equipment, and prevention and care of puncture wounds and lacerations. With the potential for acquired disease from blood-borne pathogens, the need for protective measures is as essential in the cardiac catheterization laboratory as is the standard Universal Precautions, which are applied throughout the hospital. All personnel should strongly consider vaccination for hepatitis B. Maintenance of the cardiac catheterization laboratory environment includes appropriate cleaning, limitation of traffic, and adequate ventilation. In an SCAI survey, members recommended an update on guidelines for infection control in the cardiac catheterization laboratory. The following revision of the original 1992 guidelines is written specifically to address the increased utilization of the catheterization laboratory as an interventional suite with device implantation. In this update, infection protection is divided into sections on the patient, the laboratory personnel, and the laboratory environment. Additionally, specific CDC recommendation sections highlight recommendations from other published guidelines.
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...