Related Experiment Video
Updated: Aug 14, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Randomized comparison of operator radiation exposure during coronary angiography and intervention by radial or
Helmut W Lange1, Heiner von Boetticher
1Kardiologische Praxis and the Department of Radiology, Klinikum Links der Weser, Heart Center Bremen, 28277 Bremen, Germany. hwlmd@aol.com
Abstract:
Controversial data have been published on the amount of radiation exposure during radial coronary procedures. We hypothesized that in the current era, high-volume operators with optimal technique would not be exposed to higher radiation doses during radial procedures. A total of 297 patients undergoing cardiac catheterization (195 elective diagnostic coronary angiograms and 102 elective coronary interventions) were prospectively assigned in a random fashion to the radial access (RA) or femoral access (FA). All procedures were performed by the same operator with vast experience in radial procedures and standard measures for radiation protection were used. Operator radiation exposure was measured with an electronic radiation dosimeter attached to the breast pocket of the operator on the outside of the lead apron and estimates of the ambient dose equivalent were derived. For coronary angiograms, fluoroscopy time (2.8 +/- 2.1 vs. 1.7 +/- 1.4 min; P < 0.001) and dose-area product (15.1 +/- 8.4 vs. 13.1 +/- 8.5 Gy x cm(2); P < 0.05) were increased by 18% and 15%, respectively, for RA vs. FA. Operator radiation exposure was 100% higher for the RA compared to the FA (64 +/- 55 vs. 32 +/- 39 microSv; P < 0.001). For coronary interventions, fluoroscopy time (11.4 +/- 8.4 vs. 10.4 +/- 6.8 min; P = NS) and dose-area product (46.3 +/- 28.7 vs. 51.0 +/- 29.4 Gy x cm(2); P = NS) for RA and FA were not statistically different. However, operator radiation exposure was increased by 51% for the RA compared to the FA (166 +/- 188 vs. 110 +/- 115 microSv; P < 0.05). This study demonstrates that the radial approach is burdened with a 100% increase in operator radiation exposure during diagnostic coronary catheterization procedures and a 50% increase during coronary interventions, provided that no special devices for radiation protection are used. Measurements of radiation dose, such as fluoroscopy time and dose-area product, substantially underestimate the disproportionate rise in radiation exposure. Special precautions are warranted to improve radiation protection during invasive coronary procedures via the radial approach.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies VII: Vascular Imaging
Cardiac Catheterization I: Pre-Procedure Overview
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation