Thresholding in PET images of static and moving targets
Brian Yaremko1, Terence Riauka, Don Robinson
1Department of Radiation Oncology, Cross Cancer Institute, 11560 University Avenue Edmonton, Alberta T6G 1Z2, Canada.
Abstract:
Continued therapeutic gain in the treatment of non-small-cell lung cancer (NSCLC) will depend upon our ability to escalate the dose to the primary tumour while minimizing normal tissue toxicity. Both these objectives are facilitated by the accurate definition of a target volume that is as small as possible. To this end, both tumour immobilizations via deep inspiratory breath-hold, along with positron emission tomography (PET), have emerged as two promising approaches. Though PET is an excellent means of defining the general location of a tumour focus, its ability to define exactly the geometric extent of such a focus strongly depends upon selection of an appropriate image threshold. However, in clinical practice, the image threshold is typically not chosen according to consistent, well-established criteria. This study explores the relationship between image threshold and the resultant PET-defined volume using a series of F-18 radiotracer-filled hollow spheres of known internal volumes, both static and under oscillatory motion. The effects of both image threshold and tumour motion on the resultant PET image are examined. Imaging data are further collected from a series of simulated gated PET acquisitions in order to test the feasibility of a patient-controlled gating mechanism during deep inspiratory breath-hold. This study illustrates quantitatively considerable variability in resultant PET-defined tumour volumes depending upon numerous factors, including image threshold, size of the lesion, the presence of tumour motion and the scanning protocol. In this regard, when using PET in treatment planning for NSCLC, the radiation oncologist must select the image threshold very carefully to avoid either under-dosing the tumour or overdosing normal tissues.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
05:57Long-term Video Tracking of Cohoused Aquatic Animals: A Case Study of the Daily Locomotor Activity of the Norway Lobster (Nephrops norvegicus)
Published on: April 8, 2019