Related Experiment Video
Updated: Jul 12, 2026

Practical Considerations for the Design, Execution, and Interpretation of Studies Involving Whole-Bone Bending Tests of Rodent Bones
Published on: September 1, 2023
Measurements of tortuosity in stereolithographical bone replicas using audiofrequency pulses
Keith Attenborough1, Ho-Chul Shin, Qin Qin
1Department of Engineering, University of Hull, Cottingham Road, Hull HU6 7RX, United Kingdom.
Abstract:
The tortuosity of five air-filled stereolithographical cancellous bone replicas has been obtained from measurements using audiofrequency pulses in a rectangular waveguide. The data obtained from the replicas yields information about anisotropy with respect to orthogonal axes of the passages that would be marrow filled in vivo. A strong relationship has been found between the acoustically measured tortuosity and the independently measured porosity. Use of stereolithographical bone replicas has the potential to simulate perforation and thinning of cancellous bone and hence evaluate the dependence of acoustic properties on cancellous bone microstructure. As an "extreme" illustration of such use, "inverses" of the original replicas have been manufactured and acoustic measurements have been made on them. The data reveal significantly greater tortuosity of the passages that are geometrically equivalent to the original solid bone structures.