Related Experiment Video
Updated: Aug 14, 2026

Electromagnetic Source Imaging in Presurgical Evaluation of Children with Drug-Resistant Epilepsy
Published on: September 20, 2024
Simultaneous surface registration of ictal and interictal SPECT and magnetic resonance images for epilepsy studies
Erkan U Mumcuoğlu1, Fatih Nar, Yasemin Yardimci
1Informatics Institute, Middle East Technical University, Ankara, Turkey. merkan@metu.edu.tr
Background:
Subtraction of ictal and interictal single photon emission computed tomography (SPECT) images is known to be successful in localizing the seizure focus in the pre-surgical evaluation of patients with partial epilepsy. A computer-aided methods for producing subtraction ictal SPECT co-registered to the magnetic resonance image (MRI) (the SISCOM method) is commonly used. The two registrations involved in SISCOM are (1) between the ictal-interictal SPECT images, which was shown to be the more critical, and (2) between the ictal image and MRI.
Objective:
To improve the accuracy of ictal-interictal registration in SISCOM by registering all three images (ictal, interictal SPECT, MRI) simultaneously.
Methods:
The registration problem is formulated as the minimization of a cost function between three surfaces. Then, to achieve a global minimum of this cost function, the Powell algorithm with randomly distributed initial configurations is used. This technique is tested by a realistic simulation study, a phantom study and a patient study.
Results:
The results of the simulation study demonstrate that, in surface-based registration, the triple-registration method results in a smaller ictal-interictal SPECT registration error than the pair-wise registration method (P<0.05) for a range of values of the cost-function parameter. However, the improved registration error is still larger than that obtained by the normalized mutual information method (P<0.001), which is a voxel-based registration algorithm. The phantom and patient studies reveal no observable difference between registration results.
Conclusions:
Although the improved accuracy of triple registration is slightly worse than voxel-based registration, it will soon be possible to apply the results of this study in research utilizing the triple-registration principle to improving voxel-based results of ictal-interictal registration.
More Related Videos
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016