Lower anticoagulation for mechanical heart valves: experience with the ATS bileaflet valve
Guido J Van Nooten1, Yves Taeymans, Yves Van Belleghem
1Heart Centre, University Hospital, Ghent, Belgium.
Background:
The design of the bileaflet ATS (ATS Medical Inc., Minneapolis, USA) mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of the blood at the pivot area was observed using 3-D computational fluid dynamics modelling. This phenomenon could make the valve less vulnerable to clot formation in patients without major thromboembolic risk factors.
Methods:
From January 1993 to June 1999, 286 consecutive patients had the ATS valve inserted in the aortic position. Patients were divided into two groups. Group 1 comprised all patients in regular sinus rhythm with good left ventricular function (144 patients). Group 2 included patients in non-sinus rhythm and/or with large hypocontractile left ventricles (142 patients). The anticoagulation regime in group 1 was used to obtain an international normalised ratio (INR) between 1.5 and 2.5. This contrasts with our regular aim to maintain the INR strictly between 2.5 and 3.5 for all mechanical valves, as achieved in group 2.
Results:
The follow-up period (99% completeness) ranged from 18 to 84 months. Survival (Kaplan-Meier) was 97 and 98% and 92 and 81% at 1 and 5 years in group 1 and group 2, respectively (P = 0.12). Log rank analysis failed to detect a statistical difference in thromboembolism or bleeding between both groups (P > 0.05). However, trends were in favour of group 1. Univariate analysis selected poor ventricular function and an 'erratic' INR value (P = 0.002) as risk factors for death. The sole independent risk factor for bleeding was the use of aspirin (P = 0.025).
Conclusions:
The excellent group 1 data and outcome encouraged us to continue our low intensive anticoagulation regime and perhaps should be regarded as a new concept for treatment of selected mechanical valve patients.