A comparison between active- and reactive-hyperaemia-induced brachial artery vasodilation

Jaume Padilla1, Ryan A Harris, Alyce D Fly

  • 1Clinical Exercise Physiology Laboratory, Department of Kinesiology, Indiana University, Bloomington, IN 47405, USA. jpadilla@indiana.edu

The measurement of brachial artery vasodilation in response to a hyperaemic stimulus has been used extensively to assess changes in endothelial function. However, whether or not similar changes occur in response to an active hyperaemic stimulus is unknown. The purpose of the present study was to compare brachial artery vasodilation in response to an active compared with a reactive hyperaemic stimulus following a known perturbation of endothelial function. Eight apparently healthy adults were assigned to four treatment conditions in a counter-balanced design: (i) low-fat meal with active hyperaemic stimulus (LFM-A), (ii) high-fat meal with active hyperaemic stimulus (HFM-A), (iii) low-fat meal with reactive hyperaemic stimulus (LFM-R), and (iv) high-fat meal with reactive hyperaemic stimulus (HFM-R). Meals were ingested at 08:00 hours on each treatment day. Brachial artery vasodilation was assessed via ultrasound 4 h after ingestion of each meal. The active hyperaemic stimulus was induced by 5 min of rhythmic handgrip exercise, whereas reactive hyperaemia was induced by 5 min of forearm occlusion. Brachial artery vasodilation was expressed as the percentage change in diameter from baseline to post-active/reactive hyperaemia. Using a 2x2 repeated measures ANOVA, a significant stimulusxmeal interaction (P=0.025) was found. Simple main effects revealed no difference (P=0.541) in brachial artery vasodilation between LFM-A (5.75+/-1.64%) and HFM-A (6.39+/-1.45%); however, a significant decrease (P=0.014) in brachial artery vasodilation was found in the HFM-R (4.29+/-1.64%) compared with the LFM-R (7.18+/-1.13%) treatment. In conclusion, the measurement of brachial artery vasodilation in response to active hyperaemia did not detect a change in endothelial function following a single perturbation meal, whereas reactive hyperaemia did.

Related Concept Videos

Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Vascular Spasm01:16

Vascular Spasm

The vascular phase, also known as vasospasm, is the initial stage of hemostasis, crucial for preventing excessive bleeding when a blood vessel is injured. After a vessel is cut, nerves in the damaged area trigger pain and other sensory impulses. Simultaneously, the smooth muscles in the vessel wall contract, resulting in a vascular spasm. This contraction reduces the vessel's diameter at the injury site, slowing or stopping blood loss through the vessel wall. Vascular spasms typically last for...
Sites for measuring blood pressure01:21

Sites for measuring blood pressure

Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Vascular Resistance01:20

Vascular Resistance

Vascular resistance is a critical concept in understanding blood flow dynamics in the circulatory system. It refers to the resistance that blood encounters as it flows through the blood vessels. This resistance is a key factor in determining blood pressure and cardiac workload.
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...