Direct analysis of bromide in human serum by capillary electrophoresis
Jennifer P Pascali1, Maristella Trettene, Federica Bortolotti
1Department of Medicine and Public Health, Unit of Forensic Medicine, University Hospital (Policlinico), Piazzale L.A. Scuro, 37134 Verona, Italy.
Abstract:
The purpose of the present work was the development and validation of a simple, rapid and reliable method for direct bromide quantification in serum based on capillary electrophoresis (CE). The analysis was carried out with an automated capillary electropherograph. Analytical conditions were as follows. Capillary: uncoated fused silica, effective length 50 cm, internal diameter 50 microm; voltage: 20 kV in reverse polarity mode; temperature: 25 degrees C; running buffer: 90 mmol/L sodium tetraborate decahydrate and 10 mmol/L NaCl, pH 9.24; detection: direct UV absorption at 200 nm; sample treatment: dilution of serum 1:10 with the internal standard solution (2 mmol/L thiocyanate). Under the described conditions, bromide ions and internal standard were baseline separated in 7 min. No interferences from other serum components were observed. The analytical sensitivity was characterized by a LOD: 0.05 mmol/L and a LOQ of 0.1 mmol/L. Excellent linearity was verified in the range from 2.5 to 60 mmol/L [y = 0.0746x - 0.0372; R2 = 0.9995 (x = bromide concentration; y = bromide peak area/internal standard (I.S.) peak area)]. Quantitative imprecision in intra-day (n = 7) and day-to-day (n = 7) experiments was always within R.S.D. values <2%. Recovery was quantitative throughout the range of linearity of the method. Clinical cases of infants undergoing potassium bromide therapy for refractory epilepsy were analyzed with results in agreement with literature data. On the basis of these considerations, capillary electrophoresis can be proposed as the method of choice for bromide analysis in serum samples, especially for therapeutic drug monitoring purposes.
More Related Videos
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...