Objectives:
We sought to investigate the effect of intrinsic conduction over the right bundle on the maximum rate of left ventricular pressure rise (LVdP/dt(max)) during left ventricular (LV) pacing compared to biventricular (BiV) pacing.
Background:
Simultaneous BiV pacing and LV pacing both improve LV function in patients with heart failure and LV asynchrony. We studied the hemodynamic effect of intrinsic conduction leading to ventricular fusion during LV pacing.
Methods:
In 34 patients with New York Heart Association functional class III or IV, sinus rhythm with normal atrioventricular (AV) conduction, left bundle branch block, QRS >130 ms, and optimal medical therapy, LVdP/dt(max) was measured invasively during LV and simultaneous BiV pacing. The AV interval was varied in four steps starting (AV1) with an AV interval 40 ms shorter than the intrinsic PQ time and decreased with 25% for each step.
Results:
At AV1, LVdP/dt(max) was 996 +/- 194 mm Hg/s for LV pacing and 960 +/- 200 mm Hg/s for BiV pacing (p = 0.0009), with all patients showing ventricular fusion during LV pacing. At AV2, 21 patients had ventricular fusion with a LVdP/dt(max) of 983 +/- 213 mm Hg/s and 957 +/- 202 mm Hg/s for LV and BiV pacing, respectively. In the remaining 13 patients without fusion these values were 919 +/- 164 mm Hg/s and 957 +/- 174 mm Hg/s, respectively. The difference between LV and BiV at AV2 is significantly higher when fusion is present (p = 0.01).
Conclusions:
The LVdP/dt(max) is higher in LV than in BiV pacing provided that LV pacing is associated with ventricular fusion caused by intrinsic activation.
More Related Videos
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Electrophysiology of Normal Cardiac Rhythm
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Mitral Stenosis I: Introduction