A versatile dual-channel carbon dioxide (CO2) insufflator for various CO2)applications. The prototype
K Nakajima1, K Yasumasa, S Endo
1Department of Surgery E1, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita Osaka, 565-0871, Japan. knakajima@surg1.med.osaka-u.ac.jp
Background:
Carbon dioxide (CO2), with its rapid absorptive nature, has been proven superior to atmospheric air as an insufflating agent in various clinical settings. However, CO2 insufflation has not gained wide clinical acceptance, mainly because there has been no suitable feeding system. The authors therefore have developed a versatile "dual-channel" CO2 insufflator that facilitates wider use of CO2. The objectives of this study were to introduce the authors' prototype insufflator, to evaluate its safety and performance, and to validate CO2 application using the prototype.
Methods:
The prototype insufflator provides one CO2 inlet connected to a regular CO2 gas cylinder and two CO2 outlets positioned on the front and back of the device, respectively. The CO2 gas fed from the cylinder is pressure-regulated and divided into two independent conduits inside the device. The front outlet feeds CO2 gas for pneumoperitoneum at an electronically controlled pressure and flow rate. The back channel supplies CO2 gas at a fixed flow rate, allowing manual control of insufflation for various purposes. The device was evaluated with canine models.
Results:
The prototype was safe and performed well. The CO2 application (colonoscopy in this series) using the back channel was feasible while intact CO2 pneumoperitoneum was simultaneously maintained via the front channel. There were no device malfunctions. The serial abdominal x-rays indicated that intraluminal CO2 insufflation such as that used for CO2 colonoscopy caused less residual intestinal gas than conventional air insufflation.
Conclusions:
The dual-channel CO2 insufflator enabled two different modes of CO2 insufflation at the same time from a single CO2 cylinder. The authors are now improving the prototype to allow safer and wider usage of CO2 in the operating room.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...