On-line clearance monitoring for blood access management

N Mehmedović1

  • 1University Clinical Center Tuzla, Dialysis Department, Tuzla, Bosnia and Herzegovina. amra87@bih.net.ba

EDTNA/ERCA Journal (English Ed.)
|December 21, 2005
PubMed

On-line Clearance Monitoring (OCM) provides frequent and precise information about urea clearance values during haemodialysis. In the case of blood access recirculation, it is presumed that urea clearance values on OCM would be lower and suspect to blood access malfunction. In order to check the relation between significantly lower urea clearance values and blood access recirculation, the Kt value (Clearance x time/min) for fifteen patients on OCM, including the patients with a low Kt/V in spite of their small urea distribution volume (V) was observed. Average urea clearance was calculated indirectly using Kt value (Kt/time in minutes = average clearance ml/min) and blood access recirculation tests performed using slow/stop flow two-needle, three samples method (urea method). After comparison of the recirculation percentage to clearance value, positive correlation between high recirculation and clearance reduction was noted. OCM alongside detection of haemodialysis inefficiency is also a practical instrument for blood access management between regular monitoring. Lower OCM urea clearance values demonstrate a possible blood access problem that can be confirmed with another method. When an OCM urea clearance reading is decreased by more than 25%, undiscovered access recirculation can be suspected.

Related Concept Videos

Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...