On-line clearance monitoring for blood access management
1University Clinical Center Tuzla, Dialysis Department, Tuzla, Bosnia and Herzegovina. amra87@bih.net.ba
On-line Clearance Monitoring (OCM) provides frequent and precise information about urea clearance values during haemodialysis. In the case of blood access recirculation, it is presumed that urea clearance values on OCM would be lower and suspect to blood access malfunction. In order to check the relation between significantly lower urea clearance values and blood access recirculation, the Kt value (Clearance x time/min) for fifteen patients on OCM, including the patients with a low Kt/V in spite of their small urea distribution volume (V) was observed. Average urea clearance was calculated indirectly using Kt value (Kt/time in minutes = average clearance ml/min) and blood access recirculation tests performed using slow/stop flow two-needle, three samples method (urea method). After comparison of the recirculation percentage to clearance value, positive correlation between high recirculation and clearance reduction was noted. OCM alongside detection of haemodialysis inefficiency is also a practical instrument for blood access management between regular monitoring. Lower OCM urea clearance values demonstrate a possible blood access problem that can be confirmed with another method. When an OCM urea clearance reading is decreased by more than 25%, undiscovered access recirculation can be suspected.
On-line Clearance Monitoring (OCM) provides frequent and precise information about urea clearance values during haemodialysis. In the case of blood access recirculation, it is presumed that urea clearance values on OCM would be lower and suspect to blood access malfunction. In order to check the relation between significantly lower urea clearance values and blood access recirculation, the Kt value (Clearance x time/min) for fifteen patients on OCM, including the patients with a low Kt/V in spite of their small urea distribution volume (V) was observed. Average urea clearance was calculated indirectly using Kt value (Kt/time in minutes = average clearance ml/min) and blood access recirculation tests performed using slow/stop flow two-needle, three samples method (urea method). After comparison of the recirculation percentage to clearance value, positive correlation between high recirculation and clearance reduction was noted. OCM alongside detection of haemodialysis inefficiency is also a practical instrument for blood access management between regular monitoring. Lower OCM urea clearance values demonstrate a possible blood access problem that can be confirmed with another method. When an OCM urea clearance reading is decreased by more than 25%, undiscovered access recirculation can be suspected.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...