Related Experiment Video
Updated: Aug 14, 2026

Temperature-Controlled Assembly and Characterization of a Droplet Interface Bilayer
Published on: April 19, 2021
The temperature dependence of the heat capacity change for micellization of nonionic surfactants
1Department of Chemistry, University of Colorado at Colorado Springs, Colorado Springs, CO 80933-7150, USA. gkreshec@uccs.edu
Abstract:
The thermodynamic parameters that govern micelle formation by four different nonionic surfactants were investigated by ITC and DSC. These included n-dodecyldimethylphosphine oxide (APO12), Triton X-100 (TX-100), n-octyltetraoxyethylene (C8E4), and N,N-dimethyloctylamine-N-oxide (DAO8). All of these surfactants had been previously investigated by solution calorimetry over smaller temperature ranges with conflicting conclusions as to the temperature dependence of the heat capacity change, DeltaCp, for the process. The temperature coefficient of the heat capacity change, B (cal/mol K2), was derived from the enthalpy data that were obtained at small intervals over a broad temperature range. The values obtained for each of the surfactants at 298.2 K for DeltaCp and B were -155+/-2 and 0.50+/-0.36 (APO12), -97+/-3 and -0.24+/-0.18 (TX-100), -105+/-2 and 1.0+/-0.3 (C8E4), and -82+/-1 and 0.36+/-0.04 (DAO8), cal/mol K and cal/mol K2, respectively. The resulting B-values did not correlate with the cmc, aggregation number, or structure of the monomer in an obvious way, but they were found to reflect the relative changes in hydration of the polar and nonpolar portions of the surfactant molecule as the micelles are formed. An analysis of the data obtained from DSC scans was used to describe the temperature dependence of the critical micelle concentration, cmc. An abrupt increase in heat capacity was observed for TX-100 and C8E4 solutions of 36.5+/-0.5 and 21+/-5 cal/mol K, respectively, as the temperature of the scan passed through the cloud point. This change in heat capacity may reflect the increased monomer concentration of the solutions that accompanies phase separation, although other interpretations of this jump are possible.
More Related Videos
Related Concept Videos
Micelles
Enthalpy of Solution
Surface Active Agents
Heat Capacities of an Ideal Gas I
Molar heat capacity quantifies the ratio of the amount of heat added (or removed) to increase (or decrease) the temperature of...
Heat Capacity: Problem-Solving
Determine the type of gas: The heat capacity of a gas depends on its molecular structure and the degree of freedom of its molecules. Different types of...
Membrane Fluidity

