Preload and flow propagation velocity: insight into patients with uremia and different left ventricular systolic
Shih-Hung Hsiao1, Wei-Chen Huang, Tao Yu Lee
1Division of Cardiology, Internal Medicine Department, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan, Republic of China.
Objectives:
The aim of this study was to investigate the changes of flow propagation velocity (FPV) after regular hemodialysis (H/D) in patient who were uremic with different baseline left ventricular (LV) functions.
Methods:
In all, 24 patients with uremia and abnormal LV systolic function were enrolled in this study and 30 patients with uremia and normal LV systolic performance served as the control group. All patients had in sinus rhythm and underwent a comprehensive transthoracic echocardiographic examination and mitral FPV by color M-mode echocardiography before and after H/D.
Results:
The decline in FPV before H/D was proportional to the decline in the baseline LV function, whereas FPV after H/D varied according to the LV ejection fraction. An obvious decrement of FPV for patients with normal LV systolic function was noted, but no obvious difference was seen for patients with abnormal LV systolic function.
Conclusion:
FPV was strongly preload dependent for patients with normal LV systolic function. It was not significantly influenced by preload for patients with abnormal LV systolic function. FPV is a relatively good diastolic parameter for investigating patients with LV systolic dysfunction.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias