Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020
Quality of BLS decreases with increasing resuscitation complexity
Jon C Rittenberger1, Guy Guimond, Thomas E Platt
1University of Pittsburgh Affiliated Residency in Emergency Medicine, Pittsburgh, PA, USA.
Objective:
Multiple procedures performed in parallel may cause each procedure to be performed less effectively than if performed in isolation. BLS performed by prehospital providers potentially includes artificial ventilations, chest compressions, and application of an automated external defibrillator (AED). This study examines the effectiveness of artificial ventilation and chest compressions both with and without an AED.
Methods:
Thirty-six prehospital providers participated in a prospective observational study. Tested in pairs (n=18), subjects randomly completed three, 6-min scenarios [apneic patient with a pulse (VENT), a pulseless patient (CPR), and a pulseless patient with an AED available (CPR+AED)]. A full-torso manikin capable of generating a carotid pulse was connected to a computer to record number of ventilations, tidal volume, flow rate, number of compressions, and compression depth. Data were analyzed by t-test, ANOVA, and Mann-Whitney U-test.
Results:
Artificial ventilation performed in isolation provided more correct ventilations than during CPR or CPR+AED (25.7%, 14.2%, 13.7%, p=0.02). Fewer ventilations were delivered during CPR and CPR+AED (p=0.03). More compressions were delivered with CPR alone vs. CPR+AED (51.9, 35.7 min(-1), p=0.00). More correct compressions were delivered during CPR alone vs. CPR+AED (p=0.05).
Conclusions:
Both the quality and quantity of BLS decreases as the number of procedures performed simultaneously increases. Further decrements might occur when ALS skills enter into resuscitation. These results suggest a need to automate and/or prompt the performance of BLS to optimize resuscitation.
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation IV: Pharmacological Management
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...