Related Experiment Video
Updated: Aug 14, 2026

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
In vitro estimations of in vivo jet nebulizer efficiency using actual and simulated tidal breathing patterns
Andrew P Bosco1, Rod G Rhem, Myrna B Dolovich
1Department of Medicine, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada.
Abstract:
In vivo aerosol delivery efficiency was estimated in vitro for two jet nebulizers using a breath monitor (Breathe!; Pari GmbH, Germany) and breath simulator (COMPAS; Pari GmbH) to reproduce subject tidal breathing patterns. The AeroEclipse (Trudell Medical International, Canada), a breath-actuated nebulizer, and the LC Star (Pari GmbH), a breath-enhanced nebulizer, were filled with levalbuterol HCl solution (Sepracor, USA) and operated with compressed O(2) at 8 lpm. Tidal breathing patterns of 20 adult subjects were digitally recorded with the Breathe! Breath Monitor. Subjects then breathed tidally from each nebulizer separately for 1 minute and to nebulizer dryness. Levalbuterol aerosol collected on filters placed between the nebulizer and mouth was chemically assayed to determine the inspired mass (IM), wasted mass (WM) and total emitted mass (TM). Measurements were repeated using the COMPAS Breath Simulator to simulate each subject's tidal breathing pattern. IM, WM, and TM measurements using actual versus simulated tidal breathing were highly comparable for each nebulizer, except the IM (p < 0.05) from LC Star measured at nebulizer dryness. Breath simulation was an inaccurate tool for estimating the time to nebulizer dryness as simulated measurements to nebulizer dryness took significantly longer than measurements preformed with actual tidal breathing (p < 0.001). While breath simulation provides an accurate in vitro tool for estimating in vivo aerosol delivery, it should not completely replace in vivo measurements until inherent limitations in simulator operation can be overcome to provide a more clinically realistic simulation.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities
Application of Integration: Problem Solving