Related Experiment Video
Updated: Aug 14, 2026

Ultrasound Velocity Measurement in a Liquid Metal Electrode
Published on: August 5, 2015
Errors and uncertainties in the measurement of ultrasonic wave attenuation and phase velocity
Alexander N Kalashnikov1, Richard E Challis
1School of Electrical and Electronic Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK. alexander.kalashnikov@nottingham.ac.uk
Abstract:
This paper presents an analysis of the error generation mechanisms that affect the accuracy of measurements of ultrasonic wave attenuation coefficient and phase velocity as functions of frequency. In the first stage of the analysis we show that electronic system noise, expressed in the frequency domain, maps into errors in the attenuation and the phase velocity spectra in a highly nonlinear way; the condition for minimum error is when the total measured attenuation is around 1 Neper. The maximum measurable total attenuation has a practical limit of around 6 Nepers and the minimum measurable value is around 0.1 Neper. In the second part of the paper we consider electronic noise as the primary source of measurement error; errors in attenuation result from additive noise whereas errors in phase velocity result from both additive noise and system timing jitter. Quantization noise can be neglected if the amplitude of the additive noise is comparable with the quantization step, and coherent averaging is employed. Experimental results are presented which confirm the relationship between electronic noise and measurement errors. The analytical technique is applicable to the design of ultrasonic spectrometers, formal assessment of the accuracy of ultrasonic measurements, and the optimization of signal processing procedures to achieve a specified accuracy.
Related Concept Videos
The Uncertainty Principle
Propagation of Uncertainty from Random Error
Velocity and Acceleration of a Wave
The velocity of the particles can be obtained by taking the partial derivative of the position equation with respect to time. We can...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...
Deriving the Speed of Sound in a Liquid