Related Experiment Video
Updated: Aug 13, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Shielded and unshielded geometries in the search for orphan sources
Thomas Hjerpe1, Christer Samuelsson
1Department of Medical Radiation Physics, Clinical Sciences, Lund, Lund University, University Hospital, SE-221 85 Lund, Sweden. Thomas.Hjerpe@sroy.fi
Abstract:
A car-borne NaI(Tl) spectrometric system was used together with a 137Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.