[Diagnosis of intraocular foreign bodies in multidetector-CT: influence of acquisition parameters on radiation dose
B Lackner1, G Schmidinger, M Funovics
1Medizinische Universität Wien. birgit.lackner@meduniwien.ac.at
Purpose:
Determination of the influence of acquisition and reconstruction parameters on radiation dose and detectability of intraocular foreign bodies using multidetector CT (MDCT).
Materials And Methods:
Porcine eyes with intraocular foreign bodies of a 0.3-mm quartz fiber and a 0.1-mm steel wire as well as 0.5 ml of blood in the vitreous were investigated using MDCT. The tube current was 500, 250, 100, and 50 mAs; the collimation was 16 x 0.75 mm and 16 x 1.5 mm; and the pitch was 0.5 and 0.75. Image reconstruction was performed using a soft tissue (H30), a bone algorithm (H60 s), and thin (0.7 and 2 mm, respectively) and thick (2 and 4 mm, respectively) reconstruction increments. The resulting data sets were then used to determine the signal difference to noise ratio (SDNR) between the foreign body and adjacent vitreous.
Results:
Changes in tube current resulted in a proportional change in the radiation dose but only in the SDNR within a range of 1:2. Reducing the collimation from 1.5 mm to 0.75 mm resulted in a doubling of the SDNR at an approximately identical radiation dose. The series with a lower pitch at the same dose per volume showed a slightly higher SDNR. Reconstruction using a bone algorithm and thin increments resulted in an increase in the mean SDNR by a factor of 1.8 to 2.3.
Conclusion:
When diagnosing small intraocular foreign bodies using MDCT, the following parameters can yield an adequate SDNR while minimizing radiation exposure: tube current 50 mAs, pitch 0.5, collimation 16 x 0.75, bone algorithm, and reconstruction increment 0.7 mm.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies for Cardiovascular System V: CT