Related Experiment Video
Updated: Aug 13, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a
P Cappa1, S A Sciuto, S Silvestri
1Department of Mechanical and Industrial Engineering, University of Rome Roma Tre, Via della Vasca Navale 79, 00146, Rome, Italy. Paulo.cappa@uniroma1.it
Abstract:
Pulmonary ventilators for intensive care provide information on, among many other patient respiratory parameters, patient resistance, compliance and 'work of breathing' values calculated from pressure and flow data patterns according to a widely utilized algorithm. The effects induced by the breathing circuit and analogue filtering of the ventilator measuring system are experimentally investigated during controlled ventilation. Three main phenomena are observed: (a) errors in calculation of resistance and compliance due to filtering of pressure and flow waveforms; (b) the presence of pressure oscillations at the beginning of inspiration and expiration phases; and (c) the phase shift between pressure and flow waveforms. The experimental evaluation of the measuring system of a neonatal ventilator is then conducted and: (a) a delay in pressure and flow measurement synchronization equal to 22 +/- 2 ms is evaluated; moreover, (b) a difference between the values provided by the ventilator and those measured by the reference experimental setup on respiratory parameters such as the compliance, resistance and work of breathing that lies in the range of 7-16% of reading is observed.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...