[Fatal course after osteosynthesis in a 18-year-old male]
M Dinkel1, K Glaser, F von Hoch
1Fachbereich Anästhesie, Herz- und Gefässklinik GmbH, Bad Neustadt/Saale, Germany. caan@herzchirurgie.de
Abstract:
A previously healthy patient became comatose 8 h after osteosynthesis of a fractured femur and humerus. After an initially normal cranial computed tomography, extended lesions were found 10 h later in the control scan as an indication of an embolization in the basilar artery. After neurosurgeons assessed the situation to be unfavorable, no other interventions were conducted and 6 days later brain death was confirmed. During the subsequent heart transplantation the suspicion of a patent foramen ovale as the reason for the paradoxical cerebral embolization was confirmed. This tragic course raises the question whether a patent foramen ovale should be excluded or closed by interventional measures in similar situations.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...