Objective:
We tested whether gadolinium-based contrast agent is less nephrotoxic than iodinated-contrast media.
Background:
Iodinated contrast agents are nephrotoxic. Some data suggest that gadolinium-based contrast agent may be less nephrotoxic than iodinated-contrast media.
Methods:
Twenty-five consecutive patients with chronic renal insufficiency (creatinine concentration > or = 2.0 mg/dl and/or clearance < or = 40 ml/min), referred to our institution for coronary procedures, were assigned to receive gadolinium-based contrast agents, a solution of gadolinium chelates diluted 3:1 by iso-osmolality contrast media (Gadolinium-based group). A control group of 32 patients with comparable clinical characteristics and treated with iodinated iso-osmolality contrast agent alone (Iodinated-based group) was selected from our database and compared with the Gadolinium-based group. In all cases, prophylactic administration of 0.45% saline intravenously and NAC (1200 mg orally twice daily) was used.
Results:
Baseline creatinine levels and creatinine clearance were similar in the 2 groups (Gadolinium-based group = 2.30 [IQR: 2.01-2.68] mg/dl and 33 +/- 13 ml/min; Iodinated-based group = 2.24 [IQR: 2.05-2.65] mg/dl and 30 +/- 10 ml/min; P > 0.05 for all). Increase of at least 0.5 mg/dl of the creatinine concentration 48 hr after the procedure occurred in 7/25 (28%) patients in the Gadolinium-based group and in 2/32 (6.5%) patients in the Iodinated-based group (P = 0.034; OR = 4.48; 95% CI = 1.01-19.17). Renal failure requiring temporary dialysis occurred in 2 (8%) patients in the Gadolinium-based group and in none in the Iodinated-based group (P = 0.19).
Conclusions:
The strategy of gadolinium-based contrast agent administration does not seem to reduce the rate of CAN, as compared to the iodinated iso-osmolality contrast agent in patients with chronic renal insufficiency.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging