Related Experiment Video
Updated: Aug 13, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Transmembrane pressure modulation in high-volume mixed hemodiafiltration to optimize efficiency and minimize protein
L A Pedrini1, G Cozzi, P Faranna
1Nephrology and Dialysis Department, Bolognini Hospital of Seriate, Bergamo, Italy. alxpedrini@hotmail.com
Abstract:
The aim of the present study was transmembrane pressure (TMP) modulation in high-volume mixed hemodiafiltration (HDF) to optimize efficiency and minimize protein loss. The optimal flow/pressure conditions in on-line mixed HDF assisted with a feedback control of TMP were defined in this prospective randomized study in order to obtain maximal efficiency in solute removal while minimizing potential side effects. Two different TMP profiles in mixed HDF were compared in 12 unselected patients who underwent two study periods of 2 weeks each in cross-over randomized sequence: (A) constant TMP at around 300 mmHg and (B) profiled TMP, in which TMP was slowly increased from a low initial value to the maximal value. In both procedures, the mean volume exchange was 10.6+/-1.4 l/h. Mean filtration fraction was 53%. Instantaneous beta2-microglobulin (beta2-m) clearance was higher at the start of the session with profiled TMP (207+/-35 vs 194+/-28 ml/min, P<0.005), whereas no differences were found at the end (135+/-19 vs 132+/-19 ml/min). Profiled TMP resulted in a higher mean beta2-m clearance of the session (97.0+/-15.4 vs 87.8+/-18.3 ml/min, P<0.01), in lower albumin loss in the first 30 min (0.62+/-0.14 vs 0.98+/-0.18 g, P<0.0001), and, in the whole session (3.98+/-1.19 vs 5.24+/-0.77 g, P<0.001), in higher dialyzer ultrafiltration coefficients and lower resistance indexes. This study showed that the TMP feedback modulation in mixed HDF was highly effective in maintaining very high ultrafiltration rates and filtration fractions, and minimized potential side effects as a result of the improved preservation of membrane permeability and more favorable dialyzer pressure regimen.
Related Concept Videos
Dialysis
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Fluid Movement Between Compartments
Glomerular Filtration: Net Filtration Pressure
GBHP, with an average value of 55 mmHg, promotes filtration by pushing water and solutes through the filtration membrane. This is balanced by two opposing forces: CHP, a "back pressure" exerted against the filtration membrane by fluid already in the capsular space and renal tubule,...
Osmosis and Osmotic Pressure of Solutions
Physiology of the Genitourinary System II: Tubular Reabsorption and Secretion
