Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Scipione Riva-Rocci and the men behind the mercury sphygmomanometer
1Division of Cardiology, Rambam Medical Center, B. Rappaport Faculty of Medicine, Technion -- Israel Institute of Technology, Haifa, Israel. aroguin@technion.ac.il
Abstract:
The history of the blood pressure (BP) concept and measurements is described. Many scientists were involved. Among them, major triumphs were achieved by William Harvey during the early 1600s who announced that there is a finite amount of blood that circulated the body in one direction only. In the mid-1700s, Reverend Stephen Hales reported the first invasive measurement in horses and smaller animals. Poiseuille introduced in the early 1800s the mercury hydrodynometer and the mmHg units. Karl von-Vierordt described in 1855 that with enough pressure, the arterial pulse could be obliterated. He also created the sphygmograph, a pulse recorder usable for routine non-invasive monitoring on humans. In 1881, von Basch created the sphygmomanometer and the first non-invasive BP measurements. However, in 1896, Scipione Riva-Rocci developed further the mercury sphygmomanometer, almost as we know it today. The sphygmomanometer could only be used to determine the systolic BP. Observing the pulse disappearance via palpitation would only allow the measuring physician to observe the point when the artery was fully constricted. Nikolai Korotkoff was the first to observe the sounds made by the constriction of the artery in 1905.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure